2.2.3, level 2 RO process, produce direct drinking water/pure water set set equipment series product introduction (model E21-E29-DPW/water production 0.5-10m³/h)
2.2.1, level 2 RO process production of pure water/level 3 pure water/purified water complete set of equipment process flowchart (water production 0.5-10m³/h)
*2 -level RO to produce pure water set of equipment water process flow process charts and floor plans
*Tap water → booster pump 1 → fully automatic sand filter → fully automatic activated carbon filter → softening water → 5um security filter → 1RO high -pressure pump → level RO device → direct drinking water tank → pressure -booster pump 2 → 2ro high pure pump → 2 2RO → 2 Class RO device → pure water tank → frequency conversion water supply pump 3 → ozone and water mixture → terminal filter → pure water water point.
Water entry requirements: urban tap water TDS <400ppm, water supply pressure> 0.2MPa, water temperature 5-25 ° C.
Equipment installation requirements: indoor, ambient temperature of 5-30 ° C, humidity <60%, power supply specifications: 220 or 380VAC/50Hz.
Power distribution power: 10-20kWh; water production: 0.5-10m³/h option.
Applicable occasions: For all industries, colleges and universities, and primary and secondary schools, direct drinking water/pure water.
Grade 1 RO-production quality: reach the standard of direct drinking water for direct drinking water in China CJ49-2015.
Grade 2 RO production quality: reaching China's GB17323-2015 Pure purification standards.
2.2.2, level 2 RO process production of pure water/level 3 pure water/purified water set equipment 3 configuration selection table 2 (water production 0.5-10m³/h)
Core technology of production of pure water set equipment | Grade 2 RO -producing water m 2/h | DPW series level 2 RO production and drinking pure water complete set of equipment | APW3 series level 2 RO production laboratory level 3 pure water set equipment | PPW series level 2 RO production pharmaceutical purified water set set equipment |
Stage 2 RO | 0.50 | E20-DPW-2RO-0.50 | B20-APW3-2RO-0.50 | A20-PPW-2RO-0.50 |
Stage 2 RO | 0.75 | E21-DPW-2RO-0.75 | B21-APW3-2RO-0.75 | A21-PPW-2RO-0.75 |
Stage 2 RO | 1.00 | E22-DPW-2RO-1.00 | B22-APW3-2RO-1.00 | A22-PPW-2RO-1.00 |
Stage 2 RO | 1.25 | E23-DPW-2RO-1.00 | B23-APW3-2RO-1.25 | A23-PPW-2RO-1.25 |
Stage 2 RO | 1.50 | E24-DPW-2RO-1.50 | B24-APW3-2RO-1.50 | A24-PPW-2RO-1.50 |
Stage 2 RO | 2 | E25-DPW-2RO-2 | B25-APW3-2RO-2 | A25-PPW-2RO-2 |
Stage 2 RO | 4 | E26-DPW-2RO-4 | B26-APW3-2RO-4 | A26-PPW-2RO-4 |
Stage 2 RO | 6 | E27-DPW-2RO-6 | B27-APW3-2RO-6 | A27-PPW-2RO-6 |
Stage 2 RO | 8 | E28-DPW-2RO-8 | B28-APW3-2RO-8 | A28-PPW-2RO-8 |
Stage 2 RO | 10 | E29-DPW-2RO-10 | B29-APW3-2RO-10 | A29-PPW-2RO-10 |
System monitoring technology description | E-DPW-2RO-JYW1 | B-APW3-2RO-JYW2 | A-PPW-2RO-JYW3 |
2.2.3.1, Economy Type 2 RO process, produce direct drinking water/pure water set set equipment reference photos (Model E20-E24-DPW/water production 0.5-1.5m³/h)
2.2.3.3, Economy Type 2 RO process, produce direct drinking water/pure water set set equipment configuration list (model E20-E24-dpw/water production 0.5-1.5m³/h)
Production of pure water set equipment model/configuration | Class 3 pure water output m 3/h | 1 tap water increase pump one units | Specifications of sand filters/carbon filters | 5um security filter 1 units | Grade 2 RO high -voltage pump 2 units | Grade 2 RO membrane shell specifications | UV sterilization water tank volume*quantity | A constant voltage water supply pump 1 | 0.1um filter 1 | Specification of Pipeline Sterilization Oxygen Specification |
E20-DPW-2RO-0.50 | 0.50 | CHL 1-3 | 1054*2 sets | 20"*1 core | CRL 1-10 | 4040*12+3 pieces | 0.5L*2unit | CRL 1-4 | 20"*1core | 10g/h*1 station |
E21-DPW-2RO-0.75 | 0.75 | CHL 2-3 | 1254*2 sets | 20"*1 core | CRL 1-12 | 4040*13+4 pieces | 0.75L*2unit | CRL 1-4 | 20"*1core | 10g/h*1 station |
E22-DPW-2RO-1.00 | 1.00 | CHL 2-3 | 1354*2 sets | 20"*2 core | CRL 2-10 | 4040*22+3 pieces | 1L*2unit | CRL 1-4 | 20"*2core | 10g/h*1 station |
E23-DPW-2RO-1.25 | 1.25 | CHL 2-3 | 1465*2 sets | 20"*2 core | CRL 2-12 | 4040*23+4 pieces | 1.25L*2unit | CRL 2-3 | 20"*2core | 10g/h*1 station |
E24-DPW-2RO-1.5 | 1.50 | CHL 4-3 | 1665*2 sets | 20"*3 cores | CRL 3-10 | 4040*24+5 pieces | 10L*2unit | CRL 2-3 | 20"*3core | 10g/h*1 station |
Dedication: 1 set of level 2 RO monitor, model E-PW-2ro-JYW2; 1 set of pH adjustment devices; 1 setting device; | 304 stainless steel | FRP filter | 304 stainless steel | 304 stainless steel | 304 stainless steel | PE water tank | 304 stainless steel | 304 stainless steel | 304 stainless steel |
2.2.3.5, Economy Type 2 RO process, produce direct drinking water/pure water set set equipment application parameters (model E20-E24-DPW/water production 0.5-1.5m³/h)
*Water inlet requirements:
Urban tap water TDS <300ppm; water supply pressure> 0.2MPa, water temperature 5-25 ° C.
*Equipment installation requirements: indoor, the ambient temperature is 5-30 ° C, and the humidity is <60%.
*Installation site area: 10-20 square meters set
*Power supply: 220 or 380VAC/50Hz.
*Practical power 3-6kWh. Power distribution power: 10-20kWh.
*Level 1 RO water output: 0.5m³/h; 0.75m³/h; 1m³/h; 1.25m³/h; 10m³/h;
*Level 1 RO water production standard: meet China's CE94-2015 direct drinking water standard.
*Level 2 RO water output: 250m³/h; 0.5m³/h; 0.75m³/h; 1m³/h; 1.25m³/h;
*Grade RO -producing water quality standards: reach China GB17323 drinking pure water standard
*Economic set set of equipment: Water -making equipment and electrical components allocate C -level products. The FRP FRP level 2 pre -processing equipment is used, the high and low pressure pipeline uses the UPVC pipe, the water tank is made of PE, the monitoring equipment uses an integrated touch screen+PLC electrical appliance, and the service life of equipment and electrical components is designed for 10 years. It has automated water -making and water supply functions; monitoring information digital collection to realize IoT monitoring and management.
Applicable occasions: Suitable for urban tap areas with low water hardness to use its production of direct drinking water/pure water/purified water.
2.2.3.7, the level 2 RO process of the economy, the production diagram of the production of direct drinking water/pure water set set equipment (model E20-E24-DPW/water production 0.5-1.5m³/h)
2.2.3.2, Economy-level RO process production Drink-drinking water/pure water set set equipment reference photo (Model E25-E29-DPW/water production 2-10m³/h)
2.2.3.4, Economy-based level 2 RO process, production list of direct drinking water/pure water set equipment series products (model E25-E29-DPW/water production 2-10m³/h)
Production of pure water set equipment model/configuration | Grade 2 RO pure water production m³/h | 1 water booster pump | Sand filter/carbon filter specification number | 5um security filter 1 set | 2 RO high pressure pumps | Grade 2 RO membrane shell specification quantity | UV sterilization tank volume * quantity | 3 level pure water supply pump 1 | 0.1um filter 1 | Number of specifications of pipe sterilization machine |
E25-DPW-2RO-2 | 2 | CHL 2-3 | 2072*2 sets | 20"*3 cores | CRL 2-9 | 8040*1*4 pieces | 1m³L*2 | CHL 2-3 | 20 "*3 core | 20g/h*1 station |
E26-DPW-2RO-4 | 4 | CHL 4-3 | 2472*2 sets | 20"*3 cores | CRL 4-9 | 8040*2*4 pieces | 2m³L*2 sets | CHL 4-3 | 20 "*3 core | 20g/h*1 station |
E27-DPW-2RO-6 | 6 | CHL 6-3 | 3096*2 sets | 20"*5 cores | CRL 6-9 | 8040*2*6 pieces | 3m³L*2 sets | CHL 6-3 | 20 "*5 cores | 20g/h*1 station |
E28-DPW-2RO-8 | 8 | CHL 8-3 | 4096*2 sets | 20"*5 cores | CRL 8-9 | 8040*2*8 pieces | 4m³L*2 sets | CHL 8-3 | 20 "*5 cores | 20g/h*1 station |
E29-DPW-2RO-10 | 10 | CHL 12-3 | 4896*2 sets | 20"*7 cores | CRL 12-9 | 8040*3*6 pieces | 5m³L*2 sets | CHL 12-3 | 20 "*7 core | 20g/h*1 station |
Equipment: 2RO monitor 1 set, model E-PW-2RO-JYW2; 1 set of PH adjusting device; 1 set of chemical cleaning device; | 304 stainless steel | FRP glass steel | 304 stainless steel | 304 stainless steel | FRP glass steel | PE water tank | 304SS | 304SS | 304SS |
2.2.3.6 Economic RO process, production of direct drinking water/pure water equipment application parameters (model E25-E29-DPW/ water production 2-10m³/h)
* Water intake requirements for complete equipment:
Urban tap water TDS<300ppm; Water supply pressure >0.2MPa, water temperature 5-25℃.
* Equipment installation environment requirements: installed indoors, ambient temperature 5-30℃, humidity <60%.
* Installation site area: 20-50 square meters
* Current power supply :380Vac/50Hz.
* Practical power: 5-15kwh. Distribution power :15-45kwh.
* Grade 1 RO water yield (m³/h) : 3; 5; 7; 9; 11
* Grade 1 RO water quality standard: reach China CE94-2015 direct drinking water standard.
* Grade 2 RO water yield (m³/h) : 2; 4; 6; 8; 10
* Grade 2 RO water quality standard: reach China GB17323-2015 drinking water standard.
* Economical complete set of equipment features: water equipment and electrical components are configured with C-class products. Using FRP FRP 2 level pretreatment equipment, high and low pressure pipeline using UPVC pipeline, water tank using PE material, monitoring equipment using integrated touch screen +PLC electrical appliances, equipment and electrical parts service life design of 10 years. With automatic water production and water supply function; Digital collection of monitoring information to achieve Internet of Things monitoring and management.
* Application: Suitable for the production of direct drinking water/purified water/purified water in urban tap water areas with low water hardness.
2.2.3.8 Economical RO process, application diagram of complete equipment for the production of direct drinking water/pure water (Model E25-E29-DPW/ water production 2-10m³/h)
1.6B.8, basic type [BT-UPW1-2 level RO+2 EDI+3-level purely-58-] process, produce DPW direct drinking water/UPW-1-1 high-pure water central separation water/water supply all-in-one machine
2.1.4, basic type 1 RO process, production of direct drinking water complete equipment series product introduction (model B10-B19-DPW/water production 0.5-10m³/h)
1.6A.3, advanced type [AT-UPW1-2 level RO+Level 1 EDI+3-level Pure Pillar-52-] process, produce DPW direct drinking water/UPW-1-level super pure water central separation water/water supply integration machine