2.2.4.2, Basic Type 2 RO process, produce direct drinking water/3-level pure water complete set of equipment reference pictures (Model B25-B29-APW3/water production 2-10m³/h)
2.2.4.4, the basic type 2 RO process, produce direct drinking water/3-level pure water set equipment configuration list (Model B25-B29-APW3/water production 2-10m³/h)
Production medical 3 -level pure water complete set equipment model/configuration | Grade 2 RO -producing water m 2/h | 1 tap water increase pump one units | Number of sand filters/carbon filters | 5um security filter 1 units | Grade 2 RO high -voltage pump 2 units | Grade 2 RO membrane shell specification*quantity | UV sterilization water tank volume*quantity | Level 3 pure water water supply pump 1 | 0.1um filter 1 | Number of specifications of pipe sterilization machine |
B25-APW3-2RO-2 | 2 | CHL 2-3 | 2072*2 sets | 20"*3 cores | CRL 2-9 | 8040*1*4 | 1m³*2 sets | CHL 2-3 | 20 "*3 core | 20g/h*1 station |
B26-APW3-2RO-4 | 4 | CHL 4-3 | 2472*2 sets | 20"*3 cores | CRL 4-9 | 8040*2*4 | 2m³*2 sets | CHL 4-3 | 20 "*5 cores | 20g/h*1 station |
B27-APW3-2RO-6 | 6 | CHL 6-3 | 3096*2 sets | 20"*5 cores | CRL 6-9 | 8040*2*6 | 3m³*2 sets | CHL 6-3 | 20 "*5 cores | 20g/h*1 station |
B28-APW3-2RO-8 | 8 | CHL 8-3 | 4096*2 sets | 20"*5 cores | CRL 8-9 | 8040*2*8 | 4m³*2 sets | CHL 8-3 | 20 "*5 cores | 20g/h*1 station |
B29-APW3-2RO-10 | 10 | CHL 12-3 | 4896*2 sets | 20"*7 cores | CRL 12-9 | 8040*3*6 | 5m³*2 sets | CHL 12-3 | 20 "*7 core | 20g/h*1 station |
Equipment: 2RO monitor 1 set, model: B-APW-2RO-JYW2; 1 set of PH adjusting device; 1 set of cleaning device | 304SS | 304SS | 304SS | 304SS | 304SS | 304SS | 304SS | 304SS | 304SS |
2.2.4.6 Basic type 2 RO process, production of 3 level pure water complete equipment series product technical parameters (model B25-B29-APW3 / water production 2-10m³/h)
* Water intake requirements for complete equipment:
Urban tap water TDS<300ppm; Water supply pressure >0.2MPa, water temperature 5-25℃.
* Equipment installation environment requirements: installed indoors, ambient temperature 5-30℃, humidity <60%.
* Installation site area: 20-50 square meters.
* Current power supply: 380Vac/50Hz.
* Practical power: 5-15kwh. Distribution power :15-45kwh.
* Grade 1 RO water yield (m³/h) : 3; 5; 7; 9; 11
* Grade 1 RO water quality standard: reach China CE94-2015 direct drinking water standard.
* Grade 2 RO water yield (m³/h) : 2; 4; 6; 8; 10
* Grade 2 RO water quality (m³/h) : meet China GB17323-2015 drinking water standards;
* Basic equipment features: water equipment and electrical components are configured with B-class products. Using FRP FRP 2 level pretreatment equipment, low pressure pipeline using UPVC pipeline, high pressure pipeline using 304SS pipeline, water tank using PE material, monitoring equipment using integrated touch screen +PLC electrical appliances, equipment and electrical parts service life design of 10 years. With automatic water production and water supply function; Digital collection of monitoring information to achieve Internet of Things monitoring and management.
Application: Suitable for the production of direct drinking water/purified water/purified water in urban tap water areas with high water hardness.
2.2.4.8 Basic type 2 RO process, production of 3 grade pure water complete equipment series product application diagram (model B25-B29-APW3 / water production 2-10m³/h)